K7 M/W fitted with No 3 Roof Vent System complete with Stand
|
K8A Front Load fitted with No 3 Roof Vent System
|
|
|
|
 |
|
K9 Front Load
|
K11 A Front Load
|
|
 |
K12A Front Load with Single Zone Flush Mount Harco Programmable Temperature Controller |
|
|
|
Large Kiln Spefications as at 1st October 2008.
|
|
Model
|
Internal
W x D x H/mm
|
External
W x D x H/mm
|
Kg
|
Lt3
|
Ft3
|
Phase
|
Volts
|
Amps
|
KW
|
Temp °C
|
|
K7MW FL/1100-K/20A
|
460x460x460
|
970x830x900
|
175
|
97
|
3.40
|
1
|
240
|
20
|
4.8
|
1100
|
|
K7MW FL/1300-R/30A
|
460x460x460
|
970x830x900
|
175
|
97
|
3.40
|
1
|
240
|
30
|
7.2
|
1300
|
|
K7MW FL/1300-R/15A
|
460x460x460
|
970x830x900
|
175
|
97
|
3.40
|
2
|
415
|
15
|
7.2
|
1300
|
|
K7MW FL/1300-R/10A
|
460x460x460
|
970x830x900
|
175
|
97
|
3.40
|
3
|
415
|
10
|
7.2
|
1300
|
|
K7 FL/1300-R/10A
|
460x460x460
|
900x800x1690
|
300
|
97
|
3.40
|
3
|
415
|
10
|
7.2
|
1300
|
|
K7 TL/1300-R/10A
|
460x460x460
|
812x1500x965
|
360
|
97
|
3.40
|
3
|
415
|
10
|
7.2
|
1300
|
|
K8 TL/1300-R/15A
|
460x460x610
|
812x1092x1118
|
410
|
129
|
4.50
|
3
|
415
|
15
|
10.8
|
1300
|
|
K8A TL/1300-R/16.6A
|
570x570x460
|
1295x1610x1220
|
420
|
149
|
5.28
|
3
|
415
|
16.6
|
12
|
1300
|
|
K8A FL/1300-R/16.6A
|
570x570x460
|
1015x960x1960
|
350
|
149
|
5.28
|
3
|
415
|
16.6
|
12
|
1300
|
|
K8B FL/1300-R/10.8A
|
460x460x686
|
955x800x1690
|
380
|
145
|
5.06
|
3
|
415
|
15
|
10.8
|
1300
|
|
K9 FL/1300-R/14.4A
|
460x460x915
|
900x800x1690
|
460
|
193
|
6.80
|
3
|
415
|
20
|
14.4
|
1300
|
|
K9 TL/1300-R/14.4A
|
915x460x460
|
1473x1300x1220
|
460
|
193
|
6.80
|
3
|
415
|
20
|
14.4
|
1300
|
|
K10 FL/1300-R/16.5A
|
610x610x610
|
1050x995x1690
|
500
|
226
|
8.00
|
3
|
415
|
23
|
16.5
|
1300
|
|
K10 TL/1300-R/16.5A
|
610x610x610
|
965x1650x1372
|
440
|
226
|
8.00
|
3
|
415
|
23
|
16.5
|
1300
|
|
K11 FL/1300-R/18A
|
460x610x915
|
900x950x1690
|
480
|
256
|
9.00
|
3
|
415
|
25
|
18
|
1300
|
|
K11 TL/1300-R/18A
|
915x460x610
|
1473x1500x1372
|
520
|
256
|
9.00
|
3
|
415
|
25
|
18
|
1300
|
|
K11A FL/1300-R/18A
|
610x610x762
|
1050x995x1690
|
500
|
283
|
10.00
|
3
|
415
|
25
|
18
|
1300
|
|
K11A TL/1300-R/18A
|
762x610x610
|
1320x1450x1372
|
530
|
283
|
10.00
|
3
|
415
|
25
|
18
|
1300
|
|
K12 FL/1300-R/20.16A
|
610x610x915
|
1050x995x1690
|
520
|
340
|
12.00
|
3
|
415
|
28
|
20.16
|
1300
|
|
K12 TL/1300-R/20.16A
|
915x610x610
|
1473x1450x1372
|
560
|
340
|
12.00
|
3
|
415
|
28
|
20.16
|
1300
|
|
K12A FL/1300-R/28.8A
|
610x610x1372
|
1200x1025x1885
|
580
|
510
|
18.00
|
3
|
415
|
40
|
28.8
|
1300
|
|
K12A TL/1300-R/28.8A
|
1372x610x610
|
1950x1450x1372
|
620
|
510
|
18.00
|
3
|
415
|
40
|
28.8
|
1300
|
|
It is recommended that circuit breakers or fuses and electrical cables are rated at a minimum of 20% above the required amperage of the unit. Three phase kilns are 5 wire – 1 earth, 1 neutral, 3 actives. Note: We can manufacture quite a number of 2 and 3 phase kilns as single phase if you have adequate single phase power available. The same may also be done with the multi-sided octagonal kilns.
|
|